The reason for the abnormal rise in the discharge pressure in the middle of the compressor is:
1. After the first pole, the exhaust is not good;
2. The first stage inlet pressure is too high;
3. The cooling capacity of the previous polar cooler is insufficient;
4. Piston ring leakage introduced insufficient exhaust gas;
5. The impedance of the pipeline between the gas and the next pole increases;
6. The inlet and outlet cutting parts of this grade are damaged or have poor fitting or foreign matter entering.
Method of exclusion:
1. Check gas cutting and replace damaged parts;
2. Check the previous cooler;
3. Replace the piston ring;
4 check the pipeline to make it smooth;
5. Check or replace gas cutting
6. Pay attention to overload.
Follow us